Specifications
| Presentation | High quality, Double-conversion On-line UPS designed for essential power protection needs even in the most unstable power conditions. |
|---|---|
| Lead time | Usually in Stock |
| Main Input Voltage | 230 V |
|---|---|
| Other Input Voltage | 220 V 240 V |
| Main Output Voltage | 230 V |
| Other Output Voltage | 220 V 240 V |
| rated power in W | 6000 W |
| rated power in VA | 6000 VA |
| output connector type | Hard wire 3-wire (H N + E) 1 |
| number of rack unit | 5U |
| provided equipment | Basic UPS signalling RS-232 cable CD with software 1 x DC cable Rack mounting brackets Rack mounting support rails User manual USB cable |
| Number of power module filled slots | 0 |
|---|---|
| Number of power module free slots | 0 |
| redundant | No |
| colour | Black |
|---|---|
| height | 22 cm |
| width | 43.8 cm |
| depth | 61.5 cm |
| net weight | 78 kg |
| mounting location | Front |
| mounting preference | Lower |
| mounting mode | Rack-mounted |
| USB compatible | Yes |
| mounting position | Horizontal |
| input voltage limits | 110...300 V half load 176...300 V full load |
|---|---|
| number of input connectors | 1 hard wire 3-wire (1P + N + E) |
| network frequency | 40...70 Hz auto sensing |
| Maximum configurable power in VA | 6000 VA |
|---|---|
| Maximum configurable power in W | 6000 W |
| output frequency | 50/60 Hz +/- 3 Hz sync to mains |
| harmonic distortion | 1 % |
| UPS type | Double conversion online |
| Wave type | Sine wave |
| efficiency | 94 % (full load) |
| additional information | Configurable for 220 : 230 or 240 nominal output voltage |
| bypass type | Internal bypass (automatic and manual) |
| crest factor | 3 : 1 |
| product certifications | CE EAC TISI |
|---|---|
| standards | EN/IEC 62040-1 EN/IEC 62040-2 |
| ambient air temperature for operation | 0…40 °C |
|---|---|
| relative humidity | 0…95 % non-condensing |
| operating altitude | 0...3000 m |
| ambient air temperature for storage | -15…60 °C |
| storage Relative Humidity | 0…95 % Non-condensing |
| storage altitude | 0…15000 m |
| acoustic level | 55 dBA |
| heat dissipation | 1172 Btu/h |
| IP degree of protection | IP20 |
| Run Time | |
|---|---|
| battery type | Lead-acid battery |
| battery voltage | 240 V |
| number of battery filled slots | 0 |
| number of battery free slots | 0 |
| Battery recharge time | 9 h |
| battery life | 3…5 year(s) |
| battery charger power | 1170 W rated |
| battery option | SRV240RLBP-9A 1 3024 VAh SRV240RLBP-9A 2 4536 VAh SRV240RLBP-9A 3 6048 VAh SRV240RLBP-9A 4 7560 VAh SRV240RLBP-9A |
| alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
|---|---|
| control panel | Multifunction LCD status and control console |