Description for Schneider Автоматичний вимикач RESI9 25 А, 4P, крива С, 6кА R9F12425


Miniature circuit breaker Resi9This is a 4-pole switch (four poles are protected), with a rated current of 25 A and a tripping curve C. The rated breaking capacity is up to 6000 A at a voltage of 400 V AC in accordance with the EN/MEC 60898-1 standard. This product complies with the EN/MEC 60898-1 standard. The circuit breaker protects the circuit from short-circuit current and overload. Resi9 is designed for residential construction. It has an electrical endurance of up to 10,000 cycles and a mechanical endurance of up to 20,000 cycles. The operating voltage Ue is 400 V AC. The nominal insulation voltage Ui is 440 V AC. Operating frequency 50 Hz or 60 Hz. It can be mounted on a DIN rail. Its width is 8 steps of 9 mm. The color of the product is white (RAL9003). Dimensions (W) 72 mm x (H) 81 mm x (D) 72 mm. According to the standard MEK 60529, the degree of protection IP20 and IP40 in the shield. Operating temperature from -25°C to 60°C. Storage temperature from -40°C to 60°C.

Features


Main
RangeResi9
Product nameResi9 MCB
Type of product or componentAutomatic switch
Scope of product applicationProtection
Description of the poles4P
Number of protected poles4
[In] rated current25 A
Network typeAC
Uncoupling technologyThermomagnetic
Cutoff curveC
Disconnecting ability6000 A Icn at 400 V alternating current 50/60 Hz in accordance with MEK 60898-1
StandardsMEK 60898-1
Quality markEAC
Additional Information
Network frequency50/60 Hz
[Ue] nominal operating voltage400 V alternating current 50/60 Hz
Limit of magnetic disconnection5...10 x In alternating current
Restriction class3 in accordance with MEK 60898-1
[Ui] nominal insulation voltage440 V alternating current
[Uimp] nominal impulse withstand voltage4 kV
Control typeSwitch
Local alarm systemON/OFF indicator
Method of fasteningClamping
Mounting supportDIN rail
Number of modules W = 9 mm8
Height81 mm
Width72 mm
Depth72 mm
Installation depth44 mm
Net mass480 g
ColorWhite (RAL 9003)
Mechanical wear resistance20000 cycles
Electrical wear resistance10000 cycles
Connection terminalsTunnel type terminals (Top or bottom) - 1...25 mm² - rigid
Tunnel type terminals (Top or bottom) - 1...16 mm² - flexible with clamp
Tunnel type terminals (Top or bottom) - 1...16 mm² - flexible
Wire stripping length14 mm
Tightening torque2 N.m
Earth leakage protectionMissing
Environment
Degree of protectionIP20
Degree of contamination2 in accordance with MEK 60898-1
Overvoltage categoryIII
Tropical performance2 in accordance with MEK 60068-1
Relative humidity95% at 55 °C
Operating temperature of the environment-25...60 °C
Ambient air temperature for collection-40...60 °C