Free UAE Shipping On Order over100 AED
+971 52 2525774   |   [email protected] Cash on Delivery   |   Express Delivery | Free Returns | Our Location
Recently viewed items

Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 220...230 V AC coil LC1K0910M7

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control [...]
Model :LC1K0910M7
SKU :
Assured

No Return This item cannot be returned or exchanged
Cash on Delivery Cash on Delivery available
AED 43.00
Rate inclusive of VAT
Sold By : MEPKart
Fulfilled by Thomsun Industries

100%
- +
Bulk Order

  •  Condition: New

Description for Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 220...230 V AC coil LC1K0910M7


TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 220V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Specifications


Main
RangeTeSys
Product or component typeContactor
Product nameTeSys K
Device applicationControl
Contactor applicationMotor control
Resistive load
Complementary
Utilisation categoryAC-4
AC-3
AC-1
AC-3e
Poles description3P
power pole contact composition3 NO
[Ie] rated operational current20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3e for power circuit
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage220...230 V AC 50/60 Hz
Motor power kW2.2 kW at 220...230 V AC 50/60 Hz AC-3
4 kW at 380...415 V AC 50/60 Hz AC-3
4 kW at 440 V AC 50/60 Hz AC-3
4 kW at 480 V AC 50/60 Hz AC-3
4 kW at 500...600 V AC 50/60 Hz AC-3
4 kW at 660...690 V AC 50/60 Hz AC-3
2.2 kW at 400 V AC 50/60 Hz AC-4
2.2 kW at 220...230 V AC 50/60 Hz AC-3e
4 kW at 380...415 V AC 50/60 Hz AC-3e
4 kW at 440 V AC 50/60 Hz AC-3e
4 kW at 480 V AC 50/60 Hz AC-3e
4 kW at 500...600 V AC 50/60 Hz AC-3e
4 kW at 660...690 V AC 50/60 Hz AC-3e
Auxiliary contact composition1 NO
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
Associated fuse rating25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Insulation resistance> 10 MOhm for signalling circuit
Inrush power in VA30 VA (at 20 °C)
Hold-in power consumption in VA4.5 VA (at 20 °C)
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.85...1.1 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C)
Maximum operating rate3600 cyc/h
Auxiliary contacts typetype instantaneous 1 NO
Signalling circuit frequency<= 400 Hz
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Operating time10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance0.5 mm
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Environment
StandardsEN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
Product certificationsCB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Protective treatmentTC conforming to IEC 60068
TC conforming to DIN 50016
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width6.000 cm
Package 1 Length6.500 cm
Package 1 Weight178.000 g
Unit Type of Package 2S02
Number of Units in Package 250
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.149 kg
Unit Type of Package 3P06
Number of Units in Package 3800
Package 3 Height75.000 cm
Package 3 Width80.000 cm
Package 3 Length60.000 cm
Package 3 Weight154.384 kg
Contractual warranty
Warranty18 months

Features


Download ocuments

Customer Reviews


Write a review


Please login or register to review